(1) When the scaffolding pole adopts butt joint length, the docking fasteners of the scaffolding pole should be arranged in a staggered manner, and the joints of two adjacent scaffolding poles should not be set in synchronization. The staggering distance of the joints in the height direction should not be less than 500mm; the distance from the center of each joint to the main node should not be greater than 1/3 of the step distance
(2) When the scaffolding pole adopts lap joint length, the lap joint length should not be less than 1m, and should be fixed with no less than 2 rotating fasteners. The distance from the edge of the end fastener cover to the rod end shall not be less than 100mm.