Inspection and maintenance items of scaffolding

Whether the installation of the main members at each main node, and the structure of the wall, support, and door openings meet the design requirements of the construction organization;

The strength of the concrete of the engineering structure should meet the requirements of the attached support for its additional load;

The installation of all attachment support points complies with the design requirements. It is strictly forbidden to install unqualified bolts with less attachment attachment connection bolts;

All safety insurance devices have passed the inspection; the settings of power supply, cables and control cabinets are in compliance with the relevant regulations on electricity safety;

The setting and trial operation effect of the synchronization and load control system meet the design requirements; the part of the frame structure using ordinary scaffolding members is up to the required quality;

Various safety protection facilities are in place and meet the design requirements; the construction personnel at each post have been implemented;

There should be lightning protection measures in the construction area where the lifting scaffold is attached; necessary fire protection and lighting facilities should be provided for the attachment lifting scaffold;

Lifting power equipment works normally; power settings, control equipment, anti-fall devices, etc. should be protected against rain, smashing, and dust.